EC-3185 3 in 1 EC/TDS/CF soil tester is suitable for all kinds of soil gardening plants, using high-quality probes, rust and corrosion resistance. Too high or low soil organic carbon content will hinder the growth of plants. Different fertilizers will produce different soil ECs according to the characteristics of the fertilizer and the different growth stages. The TDS value indicates contact with total soluble solids in water. The lower the tds value, the solubility of heavy metal ions in water. Nutrient solution is the key to cultivation, and different crops require different nutrient solution formulas.
Features:
Mainly used for soil detection, can measure salinity, suitable for agricultural and horticultural planting.
With a small display screen, quick and convenient reading, clear display of measurement results.
Wide measuring range, high accuracy, small error, good stability, with automatic temperature compensation.
With test probes and electrode induction probes, sensitive measurement, quick response.
Portable EC/TDS/CF tester, small in size, easy to carry and convenient to operate.
Specifications:
1. Measuring range:
EC: 0.00~4.00mS/cm
CF:0.0~4.00CF
TDS: 10~4000ppm
2. Resolution:
EC: 0.01mS/cm
CF: 0.01CF
TDS: 10ppm
3. Accuracy:
EC: 2%F.S
4. Automatic Temperature Compensation: 0~50℃
5. Power Supply: 4 * 1.5V (AG13) (not included)
6. Operating Temperature: 0~50℃
7. Calibration: Manual, at one point through trimmer
8. Dimensions: 170mm 35mm 35mm
9. Weight: 100g
Operating Information :
1 . Remove the protective cap.
2 . Turn the meter on by pressing the ON key.
3 . Place the probe to the desired depth and saturate the soil if needed with deionized water. Or immerse the electrode in the solution to be tested.
4 . Waiting for the reading to stabilize.
5 . Press the "MODE" key, choice what measure you requirement.(In
turn show "EC" "CF" "ppm" on the display)
6 . Press the "HOLD" key, the reading is be kept. When repeat measuring, please press the "HOLD" key again,it automatically relieves the hold condition.
7 . After use, turn the meter off by pressing the OFF key. Rinse the electrode with distilled water to minimize contamination.
8 . Always replace the protective cap after use.
Calibration:
1.Turn on the meter. Press the "MODE" key.
2.Immerse the meter in 12880 s/cm(12.88EC) calibration solution.
3.Unscrew the battery compartment cap on the top of the meter.
4.Allow the reading to stabilize and with a small screwdriver turn the calibration trimmer until the display shows "12.88EC ".Rinse the electrode with distilled water and suck it with tissue paper.
5.Immerse the electroder in 1413 s/cm(1.41EC) calibration solution. gently shake it and wait for a stable display. The showing value and buffer solution's value is within error range.The calibration is now complete.
Package includes:
1 x EC Tester
1 x Small screwdriver
1 x English Manual
Logistics information
Our products are located in Hong Kong, China, and the logistics speed depends on your specific location. According to our experience, it usually takes about 15-20 days of transportation time
CONTACT US
RETURNS POLICY
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Morbi ut blandit risus. Donec mollis nec tellus et rutrum. Orci varius natoque penatibus et magnis dis parturient montes, nascetur ridiculus mus. Ut consequat quam a purus faucibus scelerisque. Mauris ac dui ante. Pellentesque congue porttitor tempus. Donec sodales dapibus urna sed dictum. Duis congue posuere libero, a aliquam est porta quis.
Donec ullamcorper magna enim, vitae fermentum turpis elementum quis. Interdum et malesuada fames ac ante ipsum primis in faucibus.
Curabitur vel sem mi. Proin in lobortis ipsum. Aliquam rutrum tempor ex ac rutrum. Maecenas nunc nulla, placerat at eleifend in, viverra etos sem. Nam sagittis lacus metus, dignissim blandit magna euismod eget. Suspendisse a nisl lacus. Phasellus eget augue tincidunt, sollicitudin lectus sed, convallis desto. Pellentesque vitae dui lacinia, venenatis erat sit amet, fringilla felis. Nullam maximus nisi nec mi facilisis.
SHIPPING
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Morbi ut blandit risus. Donec mollis nec tellus et rutrum. Orci varius natoque penatibus et magnis dis parturient montes, nascetur ridiculus mus. Ut consequat quam a purus faucibus scelerisque. Mauris ac dui ante. Pellentesque congue porttitor tempus. Donec sodales dapibus urna sed dictum. Duis congue posuere libero, a aliquam est porta quis.
Donec ullamcorper magna enim, vitae fermentum turpis elementum quis. Interdum et malesuada fames ac ante ipsum primis in faucibus.
Curabitur vel sem mi. Proin in lobortis ipsum. Aliquam rutrum tempor ex ac rutrum. Maecenas nunc nulla, placerat at eleifend in, viverra etos sem. Nam sagittis lacus metus, dignissim blandit magna euismod eget. Suspendisse a nisl lacus. Phasellus eget augue tincidunt, sollicitudin lectus sed, convallis desto. Pellentesque vitae dui lacinia, venenatis erat sit amet, fringilla felis. Nullam maximus nisi nec mi facilisis.

How to choose the correct size:
Step 1 Please measure your foot length carefully.

Step 2 Please choose the correct size according to your foot length and chinese size.
For example, If your foot length is 255 mm , you should choose the size 8.