High-Precision Upper And Lower Limit Over-Range Alarm Output 4-Digit Display DC Ammeter MA Meter SP42-DA0.1

2 sold in last 8 hours
mickcara
cwc0000046
In stock
$222.61
Size Guide
Color *
DC0-99.99uA
DC0-999.9uA
DC0-9.999mA
DC0-99.99mA
DC0-999.9mA
DC0-5.000A
75mV multiplier
$222.61
customers are viewing this product
Tags:

■Basic features

 

●Standard power supply AC220V/110V (optional DC24V power supply requires remarks when ordering)

●Using precision circuit to measure DC current, with high accuracy and good stability

●With zero point and full scale digital correction function

●Upper limit setting value and lower limit setting value can be set

●With over-upper limit and low-low limit two sets of relay output alarm function

●Measurement accuracy: ±0.1%F.S±2Digit (small current), ±0.3%F.S±2Digit (large current)

●Using single-row digital tube display, beautiful appearance, complete functions, simple operation

●This product is an industrial instrument, and the shell adopts a standard embedded case, which is easy to install

Appearance: height 48×width 96×thickness 110mm, panel mounting hole: height 44×width 92mm

 

■Input wiring

 

Terminals are used for input and output, as shown in the figure below:

●INPUT inputs the measured DC current, HOLD is the function selection control terminal

OUT2: Over-upper limit output relay, OUT1: Over-lower limit output relay


 

■Model selection

●Model SP42-DA100uA: Direct measurement range DC0.00-99.99uA

●Model SP42-DA0.001: Direct measurement range DC0.0-999.9uA

●Model SP42-DA0.01: Direct measuring range DC0.000-9.999mA

●Model SP42-DA0.1: Direct measuring range DC0.00-99.99mA

●Model SP42-DA1: Direct measurement range DC0.0-999.9mA

●Model SP42-DA5: Direct measurement range DC0.000-5.000A

●Model SP42-DAD: suitable for all with DC75mV shunt input, the display magnification is adjustable

 

■Function Introduction



 

The meter measures the DC current value, and the upper limit and lower limit can be set. When the measured value is greater than or equal to the upper limit, the upper limit alarm relay OUT2 outputs, and when the measured value is less than or equal to the lower limit value, the lower limit alarm relay OUT1 outputs, the measured value When between the upper limit and the lower limit, the relay does not output.

 

Generally, when the measurement is between the upper limit and the lower limit, it is qualified, and when it is greater than the upper limit or less than the lower limit, it is unqualified.If necessary, you can set the relay OUT1 as a qualified output and the relay OUT2 as an unqualified output by setting the instrument parameters.

RETURNS POLICY

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Morbi ut blandit risus. Donec mollis nec tellus et rutrum. Orci varius natoque penatibus et magnis dis parturient montes, nascetur ridiculus mus. Ut consequat quam a purus faucibus scelerisque. Mauris ac dui ante. Pellentesque congue porttitor tempus. Donec sodales dapibus urna sed dictum. Duis congue posuere libero, a aliquam est porta quis.

Donec ullamcorper magna enim, vitae fermentum turpis elementum quis. Interdum et malesuada fames ac ante ipsum primis in faucibus.

Curabitur vel sem mi. Proin in lobortis ipsum. Aliquam rutrum tempor ex ac rutrum. Maecenas nunc nulla, placerat at eleifend in, viverra etos sem. Nam sagittis lacus metus, dignissim blandit magna euismod eget. Suspendisse a nisl lacus. Phasellus eget augue tincidunt, sollicitudin lectus sed, convallis desto. Pellentesque vitae dui lacinia, venenatis erat sit amet, fringilla felis. Nullam maximus nisi nec mi facilisis.

SHIPPING

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Morbi ut blandit risus. Donec mollis nec tellus et rutrum. Orci varius natoque penatibus et magnis dis parturient montes, nascetur ridiculus mus. Ut consequat quam a purus faucibus scelerisque. Mauris ac dui ante. Pellentesque congue porttitor tempus. Donec sodales dapibus urna sed dictum. Duis congue posuere libero, a aliquam est porta quis.

Donec ullamcorper magna enim, vitae fermentum turpis elementum quis. Interdum et malesuada fames ac ante ipsum primis in faucibus.

Curabitur vel sem mi. Proin in lobortis ipsum. Aliquam rutrum tempor ex ac rutrum. Maecenas nunc nulla, placerat at eleifend in, viverra etos sem. Nam sagittis lacus metus, dignissim blandit magna euismod eget. Suspendisse a nisl lacus. Phasellus eget augue tincidunt, sollicitudin lectus sed, convallis desto. Pellentesque vitae dui lacinia, venenatis erat sit amet, fringilla felis. Nullam maximus nisi nec mi facilisis.

How to choose the correct size:

Step 1 Please measure your foot length carefully.

Step 2 Please choose the correct size according to your foot length and chinese size.

For example, If your foot length is 255 mm , you should choose the size 8.

Step 3 If you\'re not sure of the correct size, you can click chat with us!

WHATSAPP:+8613625959351

Avoir des questions? Demandez à un expert
You have successfully subscribed!