   Sepcifications:

             Pressure measuring range (relative pressure: -100 to 6000Kpa/-0.1 to 6Mpa/-14.5 to 870psi / -1 to 60bar 

Overload pressure: 6500Kpa/6.5Mpa/940psi/65bar 

Pressure accuracy: ±0.5%FS 

Pressure resolution: 1Kpa, 0.01bar, 0.1psi, 0.001Mpa (0.01Mpa during negative pressure)      

             Temperature measuring range: -10-200℃/14-392℉ 

Temperature accuracy: ± (1℃+1digit); 

Temperature resolution: 0.1℃/0.1℉ 

Optional refrigerants (83 kinds): R11, R12, R123, R124, R125, R1270, 

R13, R134A, R14, R141b, R142b, R143A, R152A, R170, R21, R218, 

R22, R227E, R23, R236E, R245C, R245, R290, R32, R401A, R401b, 

 R401C, R402A, R402b, R403A, R403b, R404A, R405A, R406A, R407A, 

R407b, 407C, R407d, R407E, R408A, R409A, R409b, R41, R410A, 

 R410b, R11A, R411b, R412A, R413A, R414A, R414b, R415A, R415b, 

 R416A, R417A, R418A, R419A, R420A, R421A, R421b, R422A, R422b, 

R422C, R422d, R423A, R424A, R425A, R426A, R427A, R428A, R50, 

R500, R501, R502, R503, R504, R507A, R508A, R508b, R509A, R600, R600A, R717 

Operating temperature: 0 to 45℃ 

Ambient humidity: 10%RH to 90%RH 

Storage temperature: -20 to 60℃ 

Power supply: 4 AA batteries (not included package )

Dimension: 204mm×116mm×65mm 

Accessories: tool box, hose (each in red, yellow and blue),      

             Operation Instructions, 4 AA alkaline batteries, temperature clamps x2       

      

     

    

   

  

 


                            Item      

                  Value      

                          Warranty      

                  12 months      

                          Customized support      

                  OEM, ODM      

                          Place of Origin      

                  China      

                          Brand Name      

                  HTI/XINTEST      

                          Model Number      

                  HT-750      

                          Product name      

                  refrigerant meter      

                          Application: pressure      

                  kPa/MPa/bar/psi      

                          Pressure resolution      

                  1Kpa, 0.01bar, 0.1psi, 0.001Mpa      

                          Pressure accuracy      

                  ±0.5%FS      

                          Temperature measuring range      

                  -10-200℃/14-392℉      

                          Temperature resolution      

                  0.1℃/0.1℉      

                          Temperature accuracy      

                  ± (1℃+1digit)      

                          Size      

                  197*116*65.5mm      

                          Preassure medium      

                  FCKW, FKW, N, H2O      

                          Relative humidity      

                  10 to 90%RH      


RETURNS POLICY

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Morbi ut blandit risus. Donec mollis nec tellus et rutrum. Orci varius natoque penatibus et magnis dis parturient montes, nascetur ridiculus mus. Ut consequat quam a purus faucibus scelerisque. Mauris ac dui ante. Pellentesque congue porttitor tempus. Donec sodales dapibus urna sed dictum. Duis congue posuere libero, a aliquam est porta quis.

Donec ullamcorper magna enim, vitae fermentum turpis elementum quis. Interdum et malesuada fames ac ante ipsum primis in faucibus.

Curabitur vel sem mi. Proin in lobortis ipsum. Aliquam rutrum tempor ex ac rutrum. Maecenas nunc nulla, placerat at eleifend in, viverra etos sem. Nam sagittis lacus metus, dignissim blandit magna euismod eget. Suspendisse a nisl lacus. Phasellus eget augue tincidunt, sollicitudin lectus sed, convallis desto. Pellentesque vitae dui lacinia, venenatis erat sit amet, fringilla felis. Nullam maximus nisi nec mi facilisis.

SHIPPING

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Morbi ut blandit risus. Donec mollis nec tellus et rutrum. Orci varius natoque penatibus et magnis dis parturient montes, nascetur ridiculus mus. Ut consequat quam a purus faucibus scelerisque. Mauris ac dui ante. Pellentesque congue porttitor tempus. Donec sodales dapibus urna sed dictum. Duis congue posuere libero, a aliquam est porta quis.

Donec ullamcorper magna enim, vitae fermentum turpis elementum quis. Interdum et malesuada fames ac ante ipsum primis in faucibus.

Curabitur vel sem mi. Proin in lobortis ipsum. Aliquam rutrum tempor ex ac rutrum. Maecenas nunc nulla, placerat at eleifend in, viverra etos sem. Nam sagittis lacus metus, dignissim blandit magna euismod eget. Suspendisse a nisl lacus. Phasellus eget augue tincidunt, sollicitudin lectus sed, convallis desto. Pellentesque vitae dui lacinia, venenatis erat sit amet, fringilla felis. Nullam maximus nisi nec mi facilisis.

How to choose the correct size:

Step 1 Please measure your foot length carefully.

Step 2 Please choose the correct size according to your foot length and chinese size.

For example, If your foot length is 255 mm , you should choose the size 8.

Step 3 If you\'re not sure of the correct size, you can click chat with us!

WHATSAPP:+8613625959351

Avoir des questions? Demandez à un expert
HT-750 Electronic Manifold Instrument Leak Detector for Air Conditioning Pressure Gauge of Refrigeration System
You have successfully subscribed!