PHS-3C Multi-parameter PH Meter Automatic Calibration Acidity Meter Bench PH Temperature Tester Water Quality Electrode Analyzer

2 sold in last 8 hours
mickcara
shenhedoubab156
In stock
$142.54
Size Guide
Color *
WHITE
$142.54
customers are viewing this product
Tags:
1.Pour asmall quantity of pH6.86. pH4.00 and oH9.18 solution into clean beakers. 2.For a particularly accurate calibration, itis advised to use two beakers for each buffer solution; the first is to be used forrinsing the electrode, the second is to be used for the calibration. In this way, the risks of contaminating the buffer solution are reduced to a minimum 3.Switch on the instrument. 4.lmmerse the electrode in a pH6.86 buffer solution, and gently shake it until the reading to stabilize 5.Press the button "CAL" until the calibration Indicator is light.Then press "PH7" until the display shows "6.86". Rinse the electrode with distilled water. 6.lmmerse the electrode in a pH 4.00 buffer solution, and gently shake it until the reading to stabilize 7.Press the button "CAL" until the calibration Indicator is light.Then press "PH4" until the display shows "4,00". Rinse the electrode with distilled water. 8.lmmerse the electrode in a PH9.18 buffer solution. Waiting for the reading to stabilize until the display reading exact 9.18. 9.The calibration of the instrument's pH range is now completeAcidity Meter Bench PH Temperature Tester Water Quality Electrode Analyzer

Desrciption:

The PHS-3C pH meter is a portable microprocessor-based pH/temperature meter. The handy key board for the selection of the various functions. The possibility of automatically correcting errors in measurement due to temperature and the extreme simplicity of regulation all serve to permit a rapid and reliable execution of calibration and measurement.The display on the front panel reveals the temperature pH readings taken by the instrument. The instrument comes supplied with a combined pH electron and a probe for the measurement and compensation of the temperature.

Specification:

1.Range:
PH: 0.00-14.00PH
Temp: 0-100℃
2.Resolution :
РH: 0.01PH
Temp: 0.1℃
3.Accuracy:
PH: ±0.02PH
Temp: ±0.5℃
4.Display:
PH: 4-digital LED
Temp: 3-digital LED
5.Automatic Temperature Compensation:0℃-50℃
6.Power Supply: In Label
7.Operating Temperature: 0℃-50℃
8.Calibration: 2 points with auto bufferrecognition

Operation:

1.Connecting AC power supply. Turn on the meter by"ON-OEF" switch located back ofthe instrumen.
2.Connect the electrode to the iack back of the instrument.
3.Remove the protective cap of electrode. Put the electrode into the measured solution to be tested.

Calibration

 

 

 

RETURNS POLICY

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Morbi ut blandit risus. Donec mollis nec tellus et rutrum. Orci varius natoque penatibus et magnis dis parturient montes, nascetur ridiculus mus. Ut consequat quam a purus faucibus scelerisque. Mauris ac dui ante. Pellentesque congue porttitor tempus. Donec sodales dapibus urna sed dictum. Duis congue posuere libero, a aliquam est porta quis.

Donec ullamcorper magna enim, vitae fermentum turpis elementum quis. Interdum et malesuada fames ac ante ipsum primis in faucibus.

Curabitur vel sem mi. Proin in lobortis ipsum. Aliquam rutrum tempor ex ac rutrum. Maecenas nunc nulla, placerat at eleifend in, viverra etos sem. Nam sagittis lacus metus, dignissim blandit magna euismod eget. Suspendisse a nisl lacus. Phasellus eget augue tincidunt, sollicitudin lectus sed, convallis desto. Pellentesque vitae dui lacinia, venenatis erat sit amet, fringilla felis. Nullam maximus nisi nec mi facilisis.

SHIPPING

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Morbi ut blandit risus. Donec mollis nec tellus et rutrum. Orci varius natoque penatibus et magnis dis parturient montes, nascetur ridiculus mus. Ut consequat quam a purus faucibus scelerisque. Mauris ac dui ante. Pellentesque congue porttitor tempus. Donec sodales dapibus urna sed dictum. Duis congue posuere libero, a aliquam est porta quis.

Donec ullamcorper magna enim, vitae fermentum turpis elementum quis. Interdum et malesuada fames ac ante ipsum primis in faucibus.

Curabitur vel sem mi. Proin in lobortis ipsum. Aliquam rutrum tempor ex ac rutrum. Maecenas nunc nulla, placerat at eleifend in, viverra etos sem. Nam sagittis lacus metus, dignissim blandit magna euismod eget. Suspendisse a nisl lacus. Phasellus eget augue tincidunt, sollicitudin lectus sed, convallis desto. Pellentesque vitae dui lacinia, venenatis erat sit amet, fringilla felis. Nullam maximus nisi nec mi facilisis.

How to choose the correct size:

Step 1 Please measure your foot length carefully.

Step 2 Please choose the correct size according to your foot length and chinese size.

For example, If your foot length is 255 mm , you should choose the size 8.

Step 3 If you\'re not sure of the correct size, you can click chat with us!

WHATSAPP:+8613625959351

Avoir des questions? Demandez à un expert
PHS-3C Multi-parameter PH Meter Automatic Calibration Acidity Meter Bench PH Temperature Tester Water Quality Electrode Analyzer
You have successfully subscribed!