     LS125 Product Features:  

  1.Replaceable probe design, support 9 UV probes.

     2.Advanced digital probe technology, it has high precision and good anti - jamming ability.  

     3.Instrument intelligent recognize probe type and adjust the display interface intelligently.  

     4.A variety of spectral range, measuring range, test hole size of the probe to adapt to different application industries.  

     5.For LED point light source, 1mm test hole can make it more convenient to measure.  

     6.Statistical functions, real-time value, maximum value, minimum value, average value, time, energy values are displayed at the same time.  

  

     Instrument Paramete LS125 UV Light Meter:  

     weight About:194g  

     Instrument size: 148mm*76mm*26mm (L*W*H)  

     Display: 240*160 dot matrix LCD  

     Power supply: 4 AAA alkaline batteries (not include)  

     Probe connection Push pull (Snap-in style),Aviation socket  

  

     Precautions:  

     1. When not in use, please power off the instrument.  

     2. Avoid contacting with corrosive materials and keep away from high humidity.  

     3. After shutdown, store it in a special packing box and keep it in a safe place. Protect the photosensitive part of the probe from polluting.  

     4. The recommended period of calibration is one year.  

     5. Because the UV probe is sensitive to humidity changes, the environment in which it is stored is important. When not in use for a long time, be sure to store the instrument in a low humidity environment.  

     6. When the instrument displays low battery, replace the battery.  

  

  Product selection and application:

              Number

     Probe model

     Band range

     Spectral response

     Application industry

             1

     UVC-X0

     UVC

     230nm-280nm

     Intensity and Energy Test of 254nm High Power Ultraviolet Germicidal UV Curing Lamp

             2

     UVCWP-X1

     230nm-280nm

     Water treatment 254nm germicidal UV Curing lamp intensity and energy test, waterproof 1m deep

             3

     UVCLED-X0

     240nm-320nm

     Strength and energy test of 260nm-285nm LED germicidal lamp

             4

     UVB-X0

     UVB

     280nm-315nm

     Intensity and energy test of 297nm, 308nm, 313nm and other UVB light sources

             5

     UVA-X1

     UVA

     260nm-400nm

     Detection of ultraviolet intensity and energy in ultraviolet aging chamber and sunlight

             6

     UVA-X0

     315nm-400nm

     UV curing, high pressure UV Curing lamp intensity and energy test

             7

     UVALED-X0

     340nm-420nm

     UV curing, UVLED surface light intensity and energy test

             8

     UVALED-X1

     340nm-420nm

     UV curing, UVLED point light intensity and energy test

             9

     UVALED-X3

     340nm-420nm

     Intensity and energy test of low power UVLED light source

         

  

  Model selection according to measuring range and size of test optical hole:

              Number

     Probe model

     Range

     Test aperture

             1

     UVC-X0

     0 - 20000μW/cm²

     Φ10mm

             2

     UVCWP-X1

             3

     UVCLED-X0

             4

     UVB-X0

             5

     UVA-X1

             6

     UVALED-X3

             7

     UVA-X0

     0- 2000mW/cm²

             8

     UVALED-X0

     0- 20000mW/cm²

             9

     UVALED-X1

     Φ1mm

         

  

Suggestions on probe collocation in typical application industries:

  

     

  

  Universal UVA+UVB probe series:

              Probe model/

Parameter

                  

      


UVB-X0 Probe

                  

      


UVA-X1 Probe

                  

      


UVA LED-X3 Probe

                 Spectral response

     280nm-315nm

Calibrated at 297nm

     260nm-400nm

λp=365nm

     340nm-420nm

Calibrated at 395nm LD light source

             Power measurement range

     46mm×16.5mm

     39mm×32mm×15mm

             Power resolution

     0-200000μW/cm²

             Energy measurement range

     0.1μW/cm²

             Record time

     0-9999999μJ/cm²

             Measurement accuracy

     0-99999s

             Sampling speed

     ±10%

             Selectable unit

     6times/s

             Diameter of test optical hole

     μW/cm²(Default),mW/cm²,W/m²

             Probe size

     Φ10mm

         

     

  


RETURNS POLICY

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Morbi ut blandit risus. Donec mollis nec tellus et rutrum. Orci varius natoque penatibus et magnis dis parturient montes, nascetur ridiculus mus. Ut consequat quam a purus faucibus scelerisque. Mauris ac dui ante. Pellentesque congue porttitor tempus. Donec sodales dapibus urna sed dictum. Duis congue posuere libero, a aliquam est porta quis.

Donec ullamcorper magna enim, vitae fermentum turpis elementum quis. Interdum et malesuada fames ac ante ipsum primis in faucibus.

Curabitur vel sem mi. Proin in lobortis ipsum. Aliquam rutrum tempor ex ac rutrum. Maecenas nunc nulla, placerat at eleifend in, viverra etos sem. Nam sagittis lacus metus, dignissim blandit magna euismod eget. Suspendisse a nisl lacus. Phasellus eget augue tincidunt, sollicitudin lectus sed, convallis desto. Pellentesque vitae dui lacinia, venenatis erat sit amet, fringilla felis. Nullam maximus nisi nec mi facilisis.

SHIPPING

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Morbi ut blandit risus. Donec mollis nec tellus et rutrum. Orci varius natoque penatibus et magnis dis parturient montes, nascetur ridiculus mus. Ut consequat quam a purus faucibus scelerisque. Mauris ac dui ante. Pellentesque congue porttitor tempus. Donec sodales dapibus urna sed dictum. Duis congue posuere libero, a aliquam est porta quis.

Donec ullamcorper magna enim, vitae fermentum turpis elementum quis. Interdum et malesuada fames ac ante ipsum primis in faucibus.

Curabitur vel sem mi. Proin in lobortis ipsum. Aliquam rutrum tempor ex ac rutrum. Maecenas nunc nulla, placerat at eleifend in, viverra etos sem. Nam sagittis lacus metus, dignissim blandit magna euismod eget. Suspendisse a nisl lacus. Phasellus eget augue tincidunt, sollicitudin lectus sed, convallis desto. Pellentesque vitae dui lacinia, venenatis erat sit amet, fringilla felis. Nullam maximus nisi nec mi facilisis.

How to choose the correct size:

Step 1 Please measure your foot length carefully.

Step 2 Please choose the correct size according to your foot length and chinese size.

For example, If your foot length is 255 mm , you should choose the size 8.

Step 3 If you\'re not sure of the correct size, you can click chat with us!

WHATSAPP:+8613625959351

Have Questions?Ask An Expert
Linshang UVALED-X3 Probe UV Sensor for LS125 UV Intensity Meter Test Irradiance And Energy For UVA And UVV Light Source
You have successfully subscribed!