PH Meter With ATC 3 in 1 PH TDS Temp Tester High Accuracy Pocket Size PH Tester 0.00-14.00 For Pools, Drinking Water, Aquariums 40% Off


 TDS/PH/EC/Temperature Meter 4 in 1


► Measuring range: pH:0.00-14.00pH; TDS: 0-19990ppm; EC: 0-19990μS/cm

► Resolution: 0.01 pH; 1ppm; 1μS/cm; 0.1℃; 0.1°F

► Accuracy: pH: +/-0.01 pH; TDS/EC: +/-2%; Temp: 0.5℃

► Batteries: 3 * 1.5V LR44 button cell (not included)

►Temp.: 0.1-60.0℃;  32.0-140.0°F

►Calibration: pH: three points automatic calibration (6.86 & 4.00 & 9.18pH); TDS: 1413μS/cm; EC: 1413μS/cm

►Auto shut off: 5 Minutes


TDS/PH/Temperature Meter 3 in 1


► Measuring range: pH:0.00-14.00 pH; TDS: 0-19990ppm

► Resolution: 0.01 pH; 1ppm; 0.1℃; 0.1°F

► Accuracy: pH: +/-0.01 pH; TDS: +/-2%; Temp: 0.5℃

► Batteries: 3 * 1.5V LR44 button cell(not included)

►Temp.: 0.1-60.0℃;  32.0-140.0°F

►Calibration: pH: three points automatic calibration (6.86 & 4.00 & 9.18pH); TDS: 1413ppm

►Auto shut off: 5 Minutes


PH/EC/Temperature Meter 3-in-1


► Measuring range: pH:0.00-14.00 pH; EC: 0-19990μS/cm

► Resolution: 0.01 pH; 1μS/cm; 0.1℃; 0.1°F

► Accuracy: pH: +/-0.01 pH; EC: +/-2%; Temp: 0.5℃

► Batteries: 3 * 1.5V LR44 button cell(not included)

►Temp.: 0.1-60.0℃;  32.0-140.0°F

►Calibration: pH: three points automatic calibration (6.86 & 4.00 & 9.18pH); EC: 1413μS/cm

►Auto shut off: 5 Minutes

How to Calibrate the PH Meter?


Take ph 6.86 standard solution calibration as an example:

1. Press the ON/OFF button to turn on the meter, and then press MODE/CAL button adjust the tester to pH mode;

2. Put the electrode into pH 6.86 standard solution, waiting for the readings to stabilize (usually 5~10 Seconds);

3. Press and hold the MODE/CAL button and release after 6 seconds;

4. Until the readings of pH 6.86 is no longer flashing, the calibration of pH 6.86 is completed;

5. Repeat the above steps if you need to calibrate pH 4.00 or pH 9.18.




How to make a standard solution?


Take ph 6.86 standard solution as an example:

1. Add the pH 6.86 buffer powder into beaker with 250ml of distilled water;

2. Stir until the powder has completely dissolved, then pH 6.86 standard solution is completed;

3. Repeat the above steps if you need to make other standard solutions.




How to use the pH meter?


1. Press the ON/OFF button to turn on the unit, and then press MODE/CAL button adjust the tester to pH mode;

2. Dip the electrode in the target solution, making sure the whole electrode is submerged;

3. Wait a few seconds for the reading to stabilize, and the LCD screen will display both temperature and PH value.

4. Dry the electrode with a cloth after use.




 


RETURNS POLICY

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Morbi ut blandit risus. Donec mollis nec tellus et rutrum. Orci varius natoque penatibus et magnis dis parturient montes, nascetur ridiculus mus. Ut consequat quam a purus faucibus scelerisque. Mauris ac dui ante. Pellentesque congue porttitor tempus. Donec sodales dapibus urna sed dictum. Duis congue posuere libero, a aliquam est porta quis.

Donec ullamcorper magna enim, vitae fermentum turpis elementum quis. Interdum et malesuada fames ac ante ipsum primis in faucibus.

Curabitur vel sem mi. Proin in lobortis ipsum. Aliquam rutrum tempor ex ac rutrum. Maecenas nunc nulla, placerat at eleifend in, viverra etos sem. Nam sagittis lacus metus, dignissim blandit magna euismod eget. Suspendisse a nisl lacus. Phasellus eget augue tincidunt, sollicitudin lectus sed, convallis desto. Pellentesque vitae dui lacinia, venenatis erat sit amet, fringilla felis. Nullam maximus nisi nec mi facilisis.

SHIPPING

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Morbi ut blandit risus. Donec mollis nec tellus et rutrum. Orci varius natoque penatibus et magnis dis parturient montes, nascetur ridiculus mus. Ut consequat quam a purus faucibus scelerisque. Mauris ac dui ante. Pellentesque congue porttitor tempus. Donec sodales dapibus urna sed dictum. Duis congue posuere libero, a aliquam est porta quis.

Donec ullamcorper magna enim, vitae fermentum turpis elementum quis. Interdum et malesuada fames ac ante ipsum primis in faucibus.

Curabitur vel sem mi. Proin in lobortis ipsum. Aliquam rutrum tempor ex ac rutrum. Maecenas nunc nulla, placerat at eleifend in, viverra etos sem. Nam sagittis lacus metus, dignissim blandit magna euismod eget. Suspendisse a nisl lacus. Phasellus eget augue tincidunt, sollicitudin lectus sed, convallis desto. Pellentesque vitae dui lacinia, venenatis erat sit amet, fringilla felis. Nullam maximus nisi nec mi facilisis.

How to choose the correct size:

Step 1 Please measure your foot length carefully.

Step 2 Please choose the correct size according to your foot length and chinese size.

For example, If your foot length is 255 mm , you should choose the size 8.

Step 3 If you\'re not sure of the correct size, you can click chat with us!

WHATSAPP:+8613625959351

Have Questions?Ask An Expert
PH Meter With ATC 3/4 in 1 PH/TDS/Temp Tester High Accuracy Digital Water Quality Tester For Pools, Drinking Water, Aquariums
You have successfully subscribed!