Tuya Smart WiFi+RS485 Metering Leakage Circuit Breaker AC230V/400V Remote Control Circuit Breaker with Undervoltage Protection

2 sold in last 8 hours
mickcara
vae000206
In stock
$161.35
Size Guide
Rated Current *
$161.35
customers are viewing this product
Tags:

Features:

High segmentation capability.

WiFI+RS485 communication,remote switching/closing, setting parameters.

Maintenance can be remotely locked, remotely unlocked, with mechanical lock.

Undervoltage protection: The undervoltage action value can be set, and the undervoltage function can be turned off.

Loss of voltage protection: When the undervoltage function is opened, there is loss of voltage protection, that is, power trip, at this time the product cannot be manually closed.

The operating values of voltage, current, leakage current and temperature can be set.

Can read real-time voltage, current, leakage current, temperature, power value, with metering function.

Manual/Automatic setting: Manual or automatic mode can be set.

Can withstand overpressure value: can operate reliablyunder overpressure (N-L:440V), and the product is not damaged.

Specifications:

Rated operating voltage: AC230V/400V

Frame grade current: 125A

Breaking Capability: lcs 6000A

Rated current In: In is 10A, 32A, 40A, 50A, 63A

Life: mechanical life 1 0000 times, electrical life 6000 times.

Operating characteristics under overpressure:

Setting range of overvoltage action value: AC240-300V

Overvoltage Recovery Uvor: AC 220-250V

Undervoltage action characteristics

Setting range of undervoltage action value: AC 140-190V

Undervoltage Recovery Value Uvur: AC 170-220V

Under voltage operation delay: 0.5S-6S

Power on again after power off: If the system is set to automatic mode, the system automatically closes when no fault is detected, and the closing time is less than 3S: If the system is set to manual mode, the system cannot automatically close.

Wiring: Clamp wiring terminals are used.

Wire cross-sectional area up to 35mm2

Installation: Install on the 35.5X75mm standard guide rail

RS485 communication Baud rate: 9600: communication address range: 1-247

Note: 

1.Due to the light and screen difference, the item's color may be slightly different from the pictures.

2.Please allow 1mm-1cm differences due to manual measurement.

Package Includes:

1x Leakage Circuit Breaker

 

RETURNS POLICY

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Morbi ut blandit risus. Donec mollis nec tellus et rutrum. Orci varius natoque penatibus et magnis dis parturient montes, nascetur ridiculus mus. Ut consequat quam a purus faucibus scelerisque. Mauris ac dui ante. Pellentesque congue porttitor tempus. Donec sodales dapibus urna sed dictum. Duis congue posuere libero, a aliquam est porta quis.

Donec ullamcorper magna enim, vitae fermentum turpis elementum quis. Interdum et malesuada fames ac ante ipsum primis in faucibus.

Curabitur vel sem mi. Proin in lobortis ipsum. Aliquam rutrum tempor ex ac rutrum. Maecenas nunc nulla, placerat at eleifend in, viverra etos sem. Nam sagittis lacus metus, dignissim blandit magna euismod eget. Suspendisse a nisl lacus. Phasellus eget augue tincidunt, sollicitudin lectus sed, convallis desto. Pellentesque vitae dui lacinia, venenatis erat sit amet, fringilla felis. Nullam maximus nisi nec mi facilisis.

SHIPPING

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Morbi ut blandit risus. Donec mollis nec tellus et rutrum. Orci varius natoque penatibus et magnis dis parturient montes, nascetur ridiculus mus. Ut consequat quam a purus faucibus scelerisque. Mauris ac dui ante. Pellentesque congue porttitor tempus. Donec sodales dapibus urna sed dictum. Duis congue posuere libero, a aliquam est porta quis.

Donec ullamcorper magna enim, vitae fermentum turpis elementum quis. Interdum et malesuada fames ac ante ipsum primis in faucibus.

Curabitur vel sem mi. Proin in lobortis ipsum. Aliquam rutrum tempor ex ac rutrum. Maecenas nunc nulla, placerat at eleifend in, viverra etos sem. Nam sagittis lacus metus, dignissim blandit magna euismod eget. Suspendisse a nisl lacus. Phasellus eget augue tincidunt, sollicitudin lectus sed, convallis desto. Pellentesque vitae dui lacinia, venenatis erat sit amet, fringilla felis. Nullam maximus nisi nec mi facilisis.

How to choose the correct size:

Step 1 Please measure your foot length carefully.

Step 2 Please choose the correct size according to your foot length and chinese size.

For example, If your foot length is 255 mm , you should choose the size 8.

Step 3 If you\'re not sure of the correct size, you can click chat with us!

WHATSAPP:+8613625959351

Have Questions?Ask An Expert
Tuya Smart WiFi+RS485 Metering Leakage Circuit Breaker AC230V/400V Remote Control Circuit Breaker with Undervoltage Protection
You have successfully subscribed!